Microvolume UV Vis Spectrophotometer, 8nm Bandwidth

Model : SP-MUV2000; SP-MUV2000I Wavelength Range : 260nm, 280nm Sample Capacity : 0.5-2μl Spectral Bandwidth : 8nm

Size(W×D×H)(mm) : 290x208x180
Microvolume

Tips: Dear customer, if you have any questions or want to know about our products, you can click the “I want to ask” button to fill in your questions.
Unsuccessful submission? Please contact info@tech2art.com

 

 

Scientific Studies

 

Documents

 

Microvolume Spectrophotometer Specifications:

Model SP-MUV2000 SP-MUV2000I
Wavelength Range Fixed wavelength: 260nm, 280nm Fixed wavelength: 260nm, 280nm
Sample Capacity 0.5-2 μL 0.5-2 μL
Optical Path 0.2nm, 1.0mm 0. 2nm, 1.0mm
Light Source/Life UV LED/8000h UV LED/8000h
Detector UV silicon photocell UV silicon photocell
Spectral Bandwidth 8nm 8nm
Absorbance Precision 0.005Abs 0.005Abs
Accuracy ±5ng or 2% ±5ng or 2%
Range 0.2-100 (Equivalent to 10mn optical path) 0.2-100 (Equivalent to 10mn optical path)
Nucleic Acid Concentration Range 2-15000ng/μL dsDNA 2-15000ng/μL dsDNA
Detection Time 5 s 5 s
OD600 Absorbance Range 0-4.000Abs 0-4.000Abs
Absorbance Stability [0, 3)≤ 0.5%, [3,4)≤ 1% [0, 3)≤ 0.5%, [3,4)≤ 1%
Absorbance Repeatability [0, 3)≤ 0.5%, [3,4)≤ 1% [0, 3)≤ 0.5%, [3,4)≤ 1%
Absorbance Accuracy [0, 3)≤ 0.005A+1%, [3,4)≤ 2% [0, 3) ≤0.005A+1%, [3,4)≤ 2%
Fluorescence Detection / Excitation wavelength: 460n

Emission wavelength: 525nm

Fluorescence Linearity / R2>0.995
Detection Repeatability / <1.5%
Stability / <1.5%
Print Built-in thermal printer Built-in thermal printer
Data Output Method USB USB
Material of Sample Base Quartz optical fiber and high hard aluminum Quartz optical fiber and high hard aluminum
Input Voltage VAC100-240V: VDC24V 2A VAC100-240V: VDC24V 2A
Power <15W (Standby: 5W) <15W (Standby: 5W)
Size(W×D×H)(mm) 290x208x180
Shipping Size(W×D×H)(mm) 500x430x290
N.W./G.W. (kg) 2.8/4.5

 

Microvolume UV Vis Spectrophotometer Features:

 

UV vis spectrophotometer is an instrument for detecting DNA, RNA, and protein concentration. A sample volume of 0.5 to 2 μl is required for each measurement, allowing fast, accurate and reproducible micro-measurements without dilution. Accessories such as cuvettes or capillaries are not required. At the end of the measurement, you can wipe off the sample directly or use a pipette to retrieve it. The procedure is quick and easy. It can also detect the concentration of OD600 bacteria/microorganisms and other culture fluids.

1. Can test 7-inch high-definition capacitive touch screen, stand-alone

2. Long-life LED light source assembly, mainly used for detecting nucleic acid concentration and purity.

3. Extremely fast testing speed. Samples can be tested at any time.

4. Long-life optical components, intelligent light source control system, no need to preheat.

5. Can store 100,000 data in each sub-catalog.

6. Detection limit as low as 0.5pg/μL in fluorometer mode (SP-MUV2000I only).