Model : ST-BVA250PV/360PV/600PV/800PV/1000PV/1200PV/1500PV/2000PV/2500PV/3000PV/4000PV/6000PV
Interior Design Pressure : -0.1~03MPa
Jacket Design Pressure : 0.3MPa
Design Temperature 150℃
Sterilization Temperature Control Precision : 0-2℃
Tips: Dear customer, if you have any questions or want to know about our products, you can click the “I want to ask” button to fill in your questions.
Unsuccessful submission? Please contact info@tech2art.com
Scientific Studies
Documents
The ST-BVA series horizontal pulse vacuum autoclave utilizes saturated steam to achieve sterilization. Through the application of pulsating vacuum, the steam deeply permeates the surfaces of articles. The combination of high pressure and high-temperature saturated steam proves highly effective in eradicating all microorganisms and their spores, establishing itself as a potent physical sterilization method. The impact of cold air on temperature is mitigated by the pulsating vacuum exhaust, ensuring thorough sterilization through vacuum dehumidification and jacket drying processes.
Model | ST-BVA250PV | ST-BVA360PV | ST-BVA600PV | ST-BVA800PV | ST-BVA1000PV | ST-BVA1200PV | ST-BVA1500PV | ST-BVA2000PV | ST-BVA2500PV | ST-BVA3000PV | ST-BVA4000PV | ST-BVA6000PV |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Capacity (L) |
255 | 360 | 600 | 800 | 1000 | 1200 | 1500 | 2000 | 2500 | 3000 | 4000 | 6000 |
Interior Design Pressure | -0.1~03MPa | |||||||||||
Jacket Design Pressure | 0.3MPa | |||||||||||
Design Temperature | 150℃ | |||||||||||
Max Working Temperature | 139℃ | |||||||||||
Max Working Pressure | 0.25MPa | |||||||||||
Vacuum Leakage Rate | ≤0.13KPa/min | |||||||||||
Final Vacuum | -96KPa | |||||||||||
Opening Pressure of the Inner Chamber Safety Valve | 0.28MPa | |||||||||||
Jacket Safety Valve Opening Pressure | 0.28MPa | |||||||||||
Sterilization Temperature Control Precision | 0-2℃ | |||||||||||
Temperature Uniformity | ±0.5℃ | |||||||||||
Negative Pressure Pulsating Vacuum Negative Value and Number | Amplitude -80~0KPa, frequency 1~99 | |||||||||||
Number of Pulsations Across Pressure | Amplitude -80~80KPa, frequency 1 | |||||||||||
Number of Positive Pressure Pulsations | 1~3 | |||||||||||
Inner Tank Size (WxH)(mm) | 550×550 | 610×610 | 610×910 | 610×910 | 610×910 | 680×1180 | 680×1180 | 900×1380 | 900×1380 | 900×1380 | 900×1380 | 900×1380 |
Depth | 850 | 1000 | 1200 | 1500 | 1800 | 1500 | 1850 | 1620 | 2050 | 2400 | 3200 | 4800 |
Overall Size (LxWxH)(mm) | 1150x1280x1800 | 1300x1350x1850 | 1500x1440x1900 | 1800x1440x1900 | 2100x1440x1900 | 1800x1480x2000 | 2100x1480x2000 | 1970x1750x2200 | 2350x1750x2200 | 2700x1750x2200 | 3500x1750x2200 | 5400x1750x2200 |
Weight (kg) | 750 | 850 | 1250 | 1350 | 1550 | 1650 | 1850 | 2300 | 2700 | 3500 | 3500 | 6200 |
Gas Consumption(Kg/c) | 18 | 22 | 35 | 47 | 55 | 65 | 80 | 106 | 132 | 132 | 132 | 132 |
Water Consumption(Kg/c) | 120 | 180 | 320 | 400 | 500 | 600 | 750 | 1000 | 1250 | 1250 | 1250 | 1250 |
Power Supply | 380V,50HZ | 380V,50HZ | 380V,50HZ | 380V,50HZ | 380V,50HZ | 380V,50HZ | 380V,50HZ | 380V,50HZ | 380V,50HZ | 380V,50HZ | 380V,50HZ | 380V,50HZ |
Consumption | 2KW+(24KW) | 2KW+(30KW) | 3KW+(48KW) | 3.5KW+(54KW) | 3.5KW | 3.5KW | 4KW | 4.5KW | 6KW | 8KW | 8KW | 12KW |
This horizontal pulse vacuum autoclaves is well-suited for various applications, including pharmaceutical and biological engineering, medical health, laboratory animals, among others. It is particularly effective in sterilizing a range of items such as utensils, aseptic clothing, rubber plugs, aluminum caps, raw materials, filters, media, and more.