pH |
Range |
-2.000-20.000pH |
-2.000-20.000pH |
_ |
Resolution |
0.001,0.01, selectable |
0.001,0.01, selectable |
_ |
Accuracy |
±0.002pH |
±0.002pH |
_ |
Calibration Points |
1 to 5 points |
1 to 5 points |
_ |
Ph Buffer Options |
USA, NIST, DIN, 5 custom buffers |
USA, NIST, DIN, 5 custom buffers |
_ |
ORP |
mV Range |
±2000.0mV |
±2000.0mV |
±2000.0mV |
Relative mV Range |
±2000.0mV |
±2000.0mV |
_ |
Resolution |
0.1mV |
0.1mV |
0.1mV |
Accuracy |
±0.2mV |
±0.2mV |
±0.2mV |
Calibration Points |
1 point |
1 point |
_ |
Ion |
Range |
_ |
0.001~30000 (depending on the range of ISE) |
0.001~30000 (depending on the range of ISE) |
Resolution |
_ |
0.001, 0.01, 0.1, 1 |
0.001, 0.01, 0.1, 1 |
Accuracy |
_ |
±0.5% F.S. (monovalent), ±1% F.S. (divalent)) |
±0.5% F.S. (monovalent), ±1% F.S. (divalent)) |
Measurement |
_ |
ppm, mg/L, mol/L, mmol/L |
ppm, mg/L, mol/L, mmol/L |
Units |
Calibration Points |
_ |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
Measurement Methods |
_ |
Direct reading, known addition, known subtraction, sample addition, sample subtraction |
Direct reading, known addition, known subtraction, sample addition, sample subtraction |
Electrode Management |
_ |
1 to 3 electrodes |
1 to 3 electrodes |
Water Hardness |
Range |
_ |
0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) |
0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) |
Resolution |
_ |
0.001, 0.01, 0.1, 1 |
0.001,0.01,0.1,1 |
Accuracy |
_ |
±1% F.S. |
±1% F.S. |
Calibration Points |
_ |
2to 5points 0.01, 0.1, 1, 10, 100mmol/L) |
2to 5points 0.01, 0.1, 1, 10, 100mmol/L) |
Temperature |
Range |
0~105°C / 32~221°F |
0~105°C / 32~221°F |
0~105°C/32~221°F |
Resolution |
0.1°C/0.1°F |
0.1°C/0.1°F |
0.1°C/0.1°F |
Accuracy |
±05°C/0.9°F |
±05°C/0.9°F |
±05°C/0.9°F |
Offset Calibration |
1 point, reading ±10°C |
1 point, reading ±10°C |
1 point, reading ±10°C |
Other Specifications |
Temperature Compensation |
0~100°C, manual or automatic |
0~100°C, manual or automatic |
0~100°C, manual or automatic |
Solution Temperature Coefficient |
25°C |
25°C |
_ |
Stability Criteria |
Standard or high-accuracy |
Standard or high-accuracy |
Standard or high-accuracy |
Calibration Due Alarm |
1to 31 days or off |
1to 31 days or off |
1to 31 days or off |
Interval Readings |
10, 30, 60 seconds, 10, 30 minutes or off |
10, 30, 60 seconds, 10, 30 minutes or off |
10, 30, 60 seconds, 10, 30 minutes or off |
Password Protection |
4digits |
4digits |
4digits |
Memory |
1000 data sets |
1000 data sets |
1000 data sets |
Communication Interface |
USB |
USB |
USB |
Connector |
BNC, 3.5 mm jack socket |
BNC, 3.5 mm jack socket |
BNC, 3.5 mm jack socket |
Display |
7 inches TFT LCD |
7 inches TFT LCD |
7 inches TFT LCD |
Power Requirements |
DC12V power adapter |
DC12V power adapter |
DC12V power adapter |
Sizes (W×D×H)(mm) |
240×220×80 |
240×220×80 |
240×220×80 |
Shipping Size (W×D×H)(mm) |
300x250x200 |
300x250x200 |
300x250x200 |
N.W./G.W. (kg) |
1.7/2.5 |
1.7/2.5 |
1.7/2.5 |