Light Source |
Single-element or multi-element hollow cathode lamp |
Lamp Holder |
Automatic switching of six-lamp platform and full-automatic collimation |
Lamp Current |
Pulse power supply |
Optical System |
Large area 1800 /mm reticle grating, fully enclosed optical system |
Wavelength Range |
190-900nm, automatic peak finding, one-button optical optimization |
Wavelength Accuracy |
≤0.15nm |
Wavelength Repeatability |
±0.1nm |
Spectral Bandwidth |
0.1/0.2/0.4/1.0/2.0nm Auto Set |
Baseline Drift |
Static ≤ 0.002 A/30 min, dynamic ≤ 0.005 A/30 min |
Absorbance Range |
0-4A |
Detector |
Imported photomultiplier tube |
Size(W×D×H)(mm) |
1016x520x576 |
Shipping Size(W×D×H)(mm) |
1270x650x720 |
N.W./G.W. (kg) |
100/125 |
Flame System |
Burner Head |
All titanium burner head, 50mm or 100mm universal burner head |
Atomizing Chamber |
Macromolecule anti-explosion and anti-corrosion atomizing chamber |
Nebulizer |
High-efficiency glass nebulizer, can also be customized |
Ignition Mode |
Microcomputer control, automatic ignition |
Gas Control |
Automatic gas control system |
Characteristic Concentration |
0.015µg/mL/1%(Cu) |
Detection Limit |
0.002µg/mL(Cu) |
Precision |
RSD≤0.5% |
Safety |
Multiple protection measures such as gas leakage alarm, automatic protection
against tempering, and automatic power failure in case of abnormality |
Graphite Furnace System |
Heating Mode |
Longitudinal heating |
Temperature Control Mode |
Longitudinal optical temperature control monitors the inner wall temperature of the graphite tube |
Temperature Range |
RT to 3000 c |
Program Temperature Control |
Automatic temperature control up to 20 stages, enrichment and concentration in the furnace up to 20 times |
Characteristic Quantity |
0.5×10–12g (CD) |
Detection Limit |
0.4×10-12g (CD) |
Precision |
RSD≤3% |
Cooling Water |
Optional cooling water circulation system |
Safety |
Graphite tube damage, water flow, air pressure alarm;
Water temperature overheat protection |
Graphite Furnace Autosampler (optional) |
Sample Tray |
130-position sample cup, 6-position reagent cup |
Injection Volume |
0.01-100µl |
Minimum Increment |
0.01µl |
Injection Volume Repeatability |
0.01 |
Duplicate Injections |
UP to 99 |
Wash Container Volume |
500mL |
Background Correction |
Deuterium Lamp Background Correction |
1A background can be corrected |
Self-priming Background Correction |
1A background can be corrected |
Data Processing |
|
Measurement Methods |
Flame method, graphite furnace method, hydride generation-atomic absorption method |
Calculation Methods of Concentration |
Standard curve method (cubic curve), automatic fitting, and standard addition method |
Repeat Measurement Times |
1–99 times, calculate the average value, and give the standard deviation and relative standard deviation |
Result Printing |
Parameter printing, data result printing, graphic printing, and word and excel documents can be exported |